China Testing Instruments Manufacturer,Whatsapp/Wechat:+8618620373879  Email: 464560351@qq.com

MEWOI-MIX6071 Laser Dust Sensor

MEWOI-MIX6071 Laser Dust Sensor

2023-07-12 09:24:44  

Target Gas: PM2.5, PM10 Range :Measurable Dust Size: 0.3μm~10μm Application: Air purifier,Air Quality Monitor,HAVC refrigeration

  • Main Features :
  • Serial No. :
Contact Us for QuotationEmail:464560351@qq.comWhatsapp: +8618620373879

Principle Introduction

MEWOI-MIX6071 Laser Dust Sensor is used to measure the dust particle (Size: 0.3μm~10μm) in the environment and output the dust density real-time value (μg/m³) of PM1.0, PM2.5, PM10. The body of the sensor is designed with ultra-thin (12mm) structure for easy and diverse installation, full metal cover for electrical shielding and built-in advanced algorithm based on optical scattering technology with light source of Laser for accurate and steady output.

Features

Long life,Small size, Real-time monitoring, Easy to install

Application

Fresh air system
Air conditioning
Vehicle air purifier
Hand held air quality inspection

Air purifier 
Air Quality Monitor 
HAVC refrigeration 
Environment Monitoring

Technical Parameters

ItemSpecification
Measurable Dust Size0.3μm~10μm
Measurement Range0-1000ug/m³
Resolution1ug/m³
Working Condition-15℃~60℃, 0-95%RH(non-condensing)
Storage Condition-30℃~70℃, 0-95%RH(non condensing)
Measurement Accuracy(PM2.5)0~80μg/m³, ±8μg/m³
80μg/m³ ~ 600μg/m³,± 15%
Condition:23±3℃,50±10%RH
Reference Instrument:PULSE Standard
Dust Source:Cigarette(8mg)
Measurement Accuracy(PM10)0~100μg/m³, ±25μg/m³
100μg/m³ ~ 600μg/m³,± 25%
Condition:23±3℃,50±10%RH
Reference Instrument:PULSE Standard
Dust Source: Cigarette(8mg)
Output Interval1s
Time of first Reading≤5s
Power SupplyDC 5V±0.3V,Ripple wave<50mV
Working Current≤90mA
Standby Current≤50μA
Dimension48x40x12mm
Digital output modeUART TTL 3.3V
MTTF30000 Hours 


Telephone
Email
Map
QQ Chat