China Testing Instruments Manufacturer,Whatsapp/Wechat:+8618620373879  Email: 464560351@qq.com

MEWOI-M9003F ultrasonic  Partial Discharge patrol Detector,with GIS,TEV Sensor
MEWOI-M9003F ultrasonic  Partial Discharge patrol Detector,with GIS,TEV Sensor
MEWOI-M9003F ultrasonic  Partial Discharge patrol Detector,with GIS,TEV Sensor
MEWOI-M9003F ultrasonic  Partial Discharge patrol Detector,with GIS,TEV Sensor
MEWOI-M9003F ultrasonic  Partial Discharge patrol Detector,with GIS,TEV Sensor
MEWOI-M9003F ultrasonic  Partial Discharge patrol Detector,with GIS,TEV Sensor
MEWOI-M9003F ultrasonic  Partial Discharge patrol Detector,with GIS,TEV Sensor
MEWOI-M9003F ultrasonic  Partial Discharge patrol Detector,with GIS,TEV Sensor

MEWOI-M9003F ultrasonic Partial Discharge patrol Detector,with GIS,TEV Sensor

2023-07-11 11:34:13  

ultrasonic Partial Discharge patrol Detector

  • Main Features :
  • Serial No. :

Contact Us For QuotationEmail:  464560351@qq.comWhatsapp&Wechat:+8618620373879

MEWOI-M9003F ultrasonic  Partial Discharge patrol Detector,GIS, TEV Sensor

INTRODUCTION

MEWOI-M9003F partial discharge locator has the advantages of independent two-channel partial discharge signal input high-definition LCD screen, easy shock-proof, high reliability and strong ability to resist high voltage impact. It is mainly used for fault diagnosis and comprehensive analysis of partial discharge. It can synchronously detect two partial discharge signals, obtain electrical and acoustic signals from different sensors, and automatically determine various parameters such as magnitude, shape and discharge times of partial discharge in real time in three-dimensional space, and analyze and count partial discharge signals. Combined with ultrasonic or ultra-high frequency sensors, it can meet the requirements of partial discharge detection and positioning of different high-voltage electrical equipment. 

Main Features

  • 45-inch high brightness LCD display, resolution: 800 × 480

  • Portable, rugged, lightweight, suitable for use in harsh environments

  • Measurement, statistics and analysis of repetitive discharge times of

  • Save experimental data and waveforms at any time and redisplay them

  • Under the condition of no power outage, carry out operation state detection and evaluation

  • Determine the position of discharge point

TECHNICAL SPECIFICATION

(1)Parallel two channels

(2)12-bit ADC, differential signal input
(3)Antialiasing Filter
(4)Channel range can be set by software
(5)Large test dynamic range
(6)The accuracy of the whole test is 0.5 dB, the resolution is high, and the minimum resolution is 0.1 dB
(7)External signal synchronization
(8)High Capacity Rechargeable Lithium Battery
(9)Dimensions: 420mm x 300mm x 230mm



Telephone